Drywall Nailing
Submitted by Building Inspection on Tue, 09/13/2005 - 4:26am.
Building Inspection
Note: This information is also available for download and home printing as a PDF file. (Requires the free Adobe Acrobat Reader)
REFERENCE: 2003 INTERNATIONAL RESIDENTIAL CODE—TABLE-R702.3.5
APPLICATION:
Use the chart to find the application that relates to your particular construction project.
TABLE R702.3.5 - Minimum Thickness and Application of Gypsum Board
| Thickness of Gypsum Board (inches)
| Application
| Orientation of Gypsum Board to Framing
| Maximum Spacing of Framing Members (inches o.c.)
| Maximum Spacing of Fasteners (inches)
| Size of Nails for Application to Wood Framing
| |
| Nailsa
| Screwsb
| |||||
| Application without adhesive | ||||||
| 3/8
| Ceilingd
| Perpendicular
| 16
| 7
| 12
| 13 gage, 1-1/4" long, 19/64" head; 0.098 diameter, 1-1/4" long, annular-ringed; or 4d cooler nail, 0.080" diameter, 1-3/8" long, 7/32" head.
|
| Wall
| Either Direction
| 16
| 8
| 16
| ||
| 1/2
| Ceiling
| Either Direction
| 16
| 7
| 12
| 13 gage, 1-3/8" long, 19/64" head; 0.098 diameter, 1-1/4" long, annular-ringed; 5d cooler nail, 0.086 diameter, 1-5/8" long, 15/64" head; or gypsum board nail, 0.086 diameter, 1-5/8" long, 9/32" head.
|
| Ceilingd
| Perpendicular
| 24
| 7
| 12
| ||
| Wall
| Either Direction
| 24
| 8
| 12
| ||
| Wall
| Either Direction
| 16
| 8
| 16
| ||
| 5/8
| Ceiling
| Either Direction
| 16
| 7
| 12
| 13 gage, 1-5/8" long, 19/64" head; 0.098 diameter, 1-3/8" long, annular-ringed; 6d cooler nail, 0.092 diameter, 1-7/8" long, 1/4" head; or gypsum board nail, 0.0915 diameter, 1-7/8" long, 19/64" head.
|
| Ceiling
| Perpendicular
| 24
| 7
| 12
| ||
| Wall
| Either Direction
| 24
| 8
| 12
| ||
| Wall
| Either Direction
| 16
| 8
| 16
| ||
| Application with Adhesive | ||||||
| 3/8
| Ceilingd
| Perpendicular
| 16
| 16
| 16
| Same as above for 3/8" gypsum board
|
| Wall
| Either Direction
| 16
| 16
| 24
| ||
| 1/2 or 5/8
| Ceiling
| Either Direction
| 16
| 16
| 16
| Same as above for 1/2" and 5/8" gypsum board, respectively
|
| Ceilingd
| Perpendicular
| 24
| 12
| 16
| ||
| Wall
| Either Direction
| 24
| 16
| 24
| ||
| two 3/8 layers
| Ceiling
| Perpendicular
| 16
| 16
| 16
| Base ply nailed as above for 1/2" gypsum board; face ply installed with adhesive
|
| Wall
| Either Direction
| 24
| 24
| 24
| ||
For SI: 1 inch = 25.4 mm
a = for application without adhesive, a pair of nails spaced not less than 2 inches apart or more than 2-1/2 inches apart may be used with the pair of nails spaced 12 inches on center.
b = Screws shall be Type S or W per ASTM C 1002 and shall be sufficiently long to penetrate wood framing not less than 5/8 inch and metal framing not less than 3/8 inch.
c = Where metal framing is used with a clinching design to receive nails by two edges of metal, the nails shall not be less than 5/8 inch longer than the gypsum board thickness and shall have ringed shanks. Where the metal framing has a nailing groove formed to receive the nails, the nails shall have barbed shanks or be 5d, 13-1/2 gage, 1-5/8 inches long, 1-5/64-inch head for 1/2 inch gypsum board; and 6d, 13 gage, 1-7/8 inches long, 15/64-inch head for 5/8-inch gypsum board.
d = Three-eighths-inch-thick single-ply gypsum board shall not be used on a ceiling where a water-based textured finish is to be applied, or where it will be required to support insulation above a ceiling. On ceiling applications to receive a water-based texture material, either hand or spray applied, the gypsum board shall be applied perpendicular to framing. When applying a water-based texture material, the minimum gypsum board thickness shall be increased from 3/8 inch to 1/2 inch for 16-inch on center framing, and from 1/2 inch to 5/8 inch for 24-inch on center framing or 1/2-inch sag-resistant gypsum board shall be used.